BIOGAZ - instalacje i oczyszczalnie biogazu. Projektowanie instalacji biogazowych

Masz ścieki - możesz zamienić korzyści!

Zamień problem na zysk

An example of calculation of biogas receipt

A campaign variant from the food industry

 

WASTEWATER

 

Unit

Input

Output

Campaign

Beyond the campaign

Campaign

Beyond the campaign

Flow

m3/d

10080

3500

10080

3500

COD

kg/d

82000

62000

16400

9300

N

kg/d

2756

3522

1264

102

P

kg/d

567

82

240

20

ME

kg/d

6930

1785

3528

1224

 

BIOLOGICAL SLUDGE

 

Unit

Input

Output

Estimated production

kg/d

0-1500

600

 

ELECTRIC POWER

 

Unit

Input

Output

Electric power

kW/d

1435

62400

 

THERMAL ENERGY

 

Unit

Input

Output

Campaign

Beyond the campaign

Campaign

Beyond the campaign

 

kW/d

145000

115000

204191

134534

Hot water for the plant

kW/d

 

0

7433

47090

 

BIOGAS

 

Unit

Input

Output

Campaign

Beyond the campaign

Campaign

Beyond the campaign

 

kW/d

0

0

43906

3275

 

WATER

 

Unit

 

Consumption only for operation of the system

l/d

0-5000